Home
Společnost
Kontakt
PDU
Basic
Double Pole Switch
Light Indicator
Surge Protection / RFI Filter
MCB / RCB Protection
Metered
1 phase - 32A
3 phase - 3x16A
3 phase - 3x32A
Monitored
French outlets - UTE
German outlets - Schuko
IEC320C13 outlets
IEC320C13 lock outlets
IEC320C13 fuse outlets
IEC320C19 outlets
In-Line
Automatic Transfer Switch
Mediaport
Napájecí kabely
Monitored PDU with German type of sockets - 16A/230VAC
  • MONITORED STRIP WITH GERMAN TYPE SOCKETS - 1U

  • 5 "schuko" sockets outlet (German standard) max. 16A/230VAC.
    Socket 45° oriented.
    Plastic elements colour: light-grey similar to RAL7035 or black similar to RAL9005.
    Natural anodized aluminium body.
    Dimension without mounting brackets WxHxD: 431x44x44mm.
    Vertical or horizontal mounting in 19” rack - 1U.
    Mounting brackets for installation in 4 orientations.
    Supply cables H05VVF.3G1,5mm² in white and black colour terminated unischuko angled plugs or IEC320C20 plugs or IEC60309 blue 1-phase 16A/230V plugs. Standard length up to 10m.
    Maximum current 16A (3 680 W).
    Mains voltage 230 VAC
    AC ammeter with 3 digits LED display.
        - Measurement range 0,1...16A.
        - Measurement accurate ±2,5%.
    Build-in web-server with monitoring of supply circuits, current load and temperature.
        - Network interface: Ethernet RJ45 (Ethernet 10/100BaseT).
        - RJ11 interface for optional temperature sensor
        - Protocols: TCP/IP, HTTP, SNMP, SMTP, Syslog, DHCP.
    Protection level IP20.
    Declaration of Conformity CE.

    Number of
    sockets

    supply plugs

    power supply cable length / plastic colour

    2 m

    3 m

    light-grey

    black

    light-grey

    black

    5

    unischuko

    MXLJ07S052

    MXLJ08S052

    MXLJ07S053

    MXLJ08S053

    IEC320C20

    MXLJ0SF052

    MXLJ0TF052

    MXLJ0SF053

    MXLJ0TF053

    IEC60309

    MXLJ0ST052

    MXLJ0TT052

    MXLJ0ST053

    MXLJ0TT053






  • MONITORED STRIP WITH GERMAN TYPE SOCKETS - 0U

  • 12, 15 or 18 "schuko" sockets outlet (German standard) max. 16A/230VAC.
    Socket 45° oriented.
    Plastic elements colour: light-grey similar to RAL7035 or black similar to RAL9005.
    Natural anodized aluminium body.
    Dimension without mounting brackets: width 44mm, length/height according to the table, depth 44mm.
    Vertical mounting in 19” rack.
    Mounting brackets for installation in 4 orientations.
    Supply cable H05VVF.3G1,5mm² in white or black colour terminated unischuko angled plug. Standard length up to 10m.
    Maximum current 16A (3 680 W).
    Mains voltage 230 VAC
    AC ammeter with 3 digits LED display.
        - Measurement range 0,1...16A.
        - Measurement accurate ±2,5%.
    Build-in web-server with monitoring of supply circuits, current load and temperature.
        - Network interface: Ethernet RJ45 (Ethernet 10/100BaseT).
        - RJ11 interface for optional temperature sensor
        - Protocols: TCP/IP, HTTP, SNMP, SMTP, Syslog, DHCP.
    Protection level IP20.
    Declaration of Conformity CE.

    Number of
    sockets

    length
    strips

    power supply cable length / sockets colour

    2 m

    3 m

    light-grey

    black

    light-grey

    black

    12

    732 mm

    MXLJ07S122

    MXLJ08S122

    MXLJ07S123

    MXLJ08S123

    15

    861 mm

    MXLJ07S152

    MXLJ08S152

    MXLJ07S153

    MXLJ08S153

    18

    990 mm

    MXLJ07S182

    MXLJ08S182

    MXLJ07S183

    MXLJ08S183








    Monitored PDU with German type of sockets - 32A/230VAC
  • MONITORED STRIP WITH GERMAN TYPE SOCKETS - 1 PHASE 32A/230V

  • 8, 16, 20, 24 or 30 "schuko" sockets outlet (German standard) max. 16A/230VAC.
    Sockets are located in 2 block. Each block is protected by circuit breaker for overload and short circuit.
    Socket 45° oriented.
    Plastic elements colour: light-grey similar to RAL7035.
    Natural anodized aluminium body.
    Dimension without mounting brackets: width 44mm, length/height according to the table, depth 70mm.
    Vertical mounting in 19” rack.
    Mounting brackets for installation in 4 orientations.
    Supply cable H05VVF.3G4,0mm² in white colour terminated IEC60309 32A plug blue 1-phase. Standard length up to 10m.
    Maximum current 32A (7360 W).
    Mains voltage 230 VAC
    Two AC ammeters with 3 digits LED display.
        - Measurement range 0,1...16A.
        - Measurement accurate ±2,5%.
    Build-in web-server with monitoring of supply circuits, current load and temperature.
        - Network interface: Ethernet RJ45 (Ethernet 10/100BaseT).
        - RJ11 interface for optional temperature sensor
        - Protocols: TCP/IP, HTTP, SNMP, SMTP, Syslog, DHCP.
    Protection level IP20.
    Declaration of Conformity CE.

    Number of
    sockets

    length
    strips

    Power supply length cable

    2 m

    3 m

    5 m

    8

    818 mm

    MXLJ1SP442

    MXLJ1SP443

    MXLJ1SP445

    16

    1162 mm

    MXLJ1SP882

    MXLJ1SP883

    MXLJ1SP885

    20

    1334 mm

    MXLJ1SPAA2

    MXLJ1SPAA3

    MXLJ1SPAA5

    24

    1506 mm

    MXLJ1SPCC2

    MXLJ1SPCC3

    MXLJ1SPCC5

    30

    1764 mm

    MXLJ1SPFF2

    MXLJ1SPFF3

    MXLJ1SPFF5






    Monitored PDU with German type of sockets - 3x16A/230VAC
  • MONITORED STRIP WITH GERMAN TYPE SOCKETS - 3 PHASE 48A (3 x 16A)

  • 18, 24 or 30 "schuko" sockets outlet (German standard) max. 16A/230VAC.
    Sockets are colour-coded by phase (black, red and grey).
    Socket 45° oriented.
    Plastic elements colour: light-grey similar to RAL7035.
    Natural anodized aluminium body.
    Dimension without mounting brackets: width 44mm, length/height according to the table, depth 44mm.
    Vertical mounting in 19” rack.
    Mounting brackets for installation in 4 orientations.
    Supply cable H05VVF.5G2,5mm² (halogen-free option available) in white colour terminated IEC309 16A plug red 3-phase. Standard length up to 10m.
    Maximum current 3x16A (11 040 W).
    Mains voltage 230 VAC
    Three AC ammeters with 3 digits LED display.
        - Measurement range 0,1...16A.
        - Measurement accurate ±2,5%.
    Build-in web-server with monitoring of supply circuits, current load and temperature.
        - Network interface: Ethernet RJ45 (Ethernet 10/100BaseT).
        - RJ11 interface for optional temperature sensor
        - Protocols: TCP/IP, HTTP, SNMP, SMTP, Syslog, DHCP.
    Protection level IP20.
    Declaration of Conformity CE.

    Number of
    sockets

    length
    strips

    Power supply length cable

    2 m

    3 m

    5 m

    18

    1172 mm

    MXLJ2SH182

    MXLJ2SH183

    MXLJ2SH185

    24

    1430 mm

    MXLJ2SH242

    MXLJ2SH243

    MXLJ2SH245

    30

    1688 mm

    MXLJ2SH302

    MXLJ2SH303

    MXLJ2SH305




    Monitored PDU with German type of sockets - 3x32A/230VAC
  • MONITORED STRIP WITH GERMAN TYPE SOCKETS - 3 PHASE 96A (3 x 32A)

  • 6, 12 or 18 "schuko" sockets outlet (German standard) max. 16A/230VAC.
    Sockets are located in 6 blocks.
    Each block is protected by circuit breaker for overload and short circuit. Tripping characteristic - type C, 16A, 1-pole.
    Socket 45° oriented.
    Plastic elements colour: light-grey similar to RAL7035.
    Natural anodized aluminium body.
    Dimension without mounting brackets: width 44mm, length/height according to the table, depth 70mm.
    Vertical mounting in 19” rack.
    Mounting brackets for installation in 4 orientations.
    Supply cable H05VVF.5G4,0mm² in white colour terminated IEC309 32A plug red 3-phase. Standard length up to 10m.
    Maximum current 3x32A (22 080 W).
    Mains voltage 230 VAC
    Six AC ammeters with 3 digits LED display.
        - Measurement range 0,1...16A.
        - Measurement accurate ±2,5%.
    Build-in web-server with monitoring of supply circuits, current load and temperature.
        - Network interface: Ethernet RJ45 (Ethernet 10/100BaseT).
        - RJ11 interface for optional temperature sensor
        - Protocols: TCP/IP, HTTP, SNMP, SMTP, Syslog, DHCP.
    Protection level IP20.
    Declaration of Conformity CE.

    Number of
    sockets

    length
    strips

    Power supply length cable

    2 m

    3 m

    5 m

    6

    1355 mm

    MXLJ3SG062

    MXLJ3SG063

    MXLJ3SG065

    12

    1613 mm

    MXLJ3SG122

    MXLJ3SG123

    MXLJ3SG125

    18

    1871 mm

    MXLJ3SG182

    MXLJ3SG183

    MXLJ3SG185